Ply Story launches ‘The Flameblock Technology’ – fire-retardant plywood built on months of Research & Development. Our mission is to safeguard 1.44 billion Indians with superior fire safety. Flameblock utilizes cutting-edge technology, offering up to 38 minutes of fire resistance and built-in protection against borer and termites.
Flameblock Technology – more than just Fire Protection.
APPLICATIONS :
Kitchens |
Lining for Refrigerated Ships & Cooling Towers |
Ship Flooring |
Boat-Building |
Bulkhead Paneling
AVAILABLE IN :
4mm | 6 mm | 9 mm | 12 mm | 16 mm | 19 mm | 25 mm
PRODUCT RANGE:
Plywood | Blockboard
GRADE :
UNO
WARRANTY :
35 Years
OUR USP :
100% Meghalaya Hardwood Species
WATER PROOF
NO CORE GAP
TERMITE PROOF
PHENOL BONDED
BORER PROOF
MARINE GRADE
FUNGUS PROOF
ECO FRIENDLY
FIRE RETARDANT
GRADE IS:5509
MOISTURE CONTENT | 6.83% |
GLUE ADHESION – WATER RESISTANCE TEST | STANDARD |
WORKMANSHIP & FINISH | SATISFACTORY |
STATIC BENDING STRENGTH (MOE) – Average | ACROSS GRAIN:5286 N/mm2 |
STATIC BENDING STRENGTH (MOE) – Minimum | ACROSS GRAIN: 5064 N/mm2 |
STATIC BENDING STRENGTH (MOR) – Average | ACROSS GRAIN: 44 N/mm2 |
STATIC BENDING STRENGTH (MOR) – Minimum | ACROSS GRAIN: 37.8 N/mm2 |
PROCESS COMPLIANT | IS:5509 (2021) |
Tests | Flammability (35 minutes) Flame Penetration (35 minutes) Rate of Burning (28 minutes) |
GRADE IS:1659
RESISTANCE TO WATER | STANDARD |
SPOT TEST | SATISFACTORY |
ADHESION OF PLIES | STANDARD |
MYCOLOGICAL TEST | NO VISIBLE SEPARATION OBSERVED |
MODULUS OF RUPTURE | Average – 43.27 N/mm2 Minimum, Individual – 41.17 N/mm2 |
MODULUS OF ELASTICITY | Average – 6881.7 N/mm2 Minimum, Individual – 6619 N/mm2 |
DIMENSIONAL CHANGES CAUSED BY HUMIDITY | NO delamination observed |
SURFACE DEFECT | SATISFACTORY |
Dimension & Tolerances | Squareness – 0.06% Edge Straightness – 0.01% Thickness – 19.66 mm Width – 1222 mm Length – 2445 mm |